Home > Products > Emergency Lighting Products > Emergency Exit Lighting > Emergency Exit Sign Lighting GS-EGSS4W

Emergency Exit Sign Lighting GS-EGSS4W

    LED Indoor Outdoor R Emergency Light LED Exit Light White 4W EGSS4W


    Technical Specifications

    Mains Supply

    220-240VAC ,50/60Hz

    Power

    4W

    Duration Time

    3 Hours

    Recharge Period

    16 Hours

    Battery Size & Type

    LiFePO4 3.2V1.5Ah

    LED Power

    0.7 W (emergency)

    1.0 W (maintained)

    CCT

    6500k

    CRI

    70

    Luminous Flux

    50 lm (emergency)

    30 lm (maintained)

    Protection Class

    Class Ⅱ

    Operating Temperature

    0-40 ℃

    Beam Angle

    N/A


Features

- Flush mounting, Wall or recessed mounting
-LiFePO4 battery, replaceable
-Non-maintained or maintained operation
-Intelligent charge and discharge
-3 hours emergency duration
-View distance 30m
-Include test switch and four legends
-CE, IP40



Materials
ABS, 850℃ glow wire test


Standard Compliance
-IEC 60598.2.22
-IEC 60598.1
-EN 55015
-EN 61000
-IEC62133

-IEC61347-2-7


Dimensions

5869df5e7f49bdcabb93209c4d627ad.jpg


Below is a list of 3 things to ask yourself when designing a system:


1. What is the primary purpose of the emergency lighting system?

The primary purpose of an emergency lighting luminaires system is to provide illumination in locations where it is necessary for the safe conduct of business or during an emergency. The different types of emergency lighting systems are designed to meet the specific needs of each kind of environment.


2. Does my building need emergency lighting?

Every class (classes) 5, 6 (six), 7, 8 or 9 building with a floor area of more than 300m² must have emergency and exit lights.


3. Where should emergency lighting be installed?

When it comes to emergency lighting, there are a few things to keep in mind. First and foremost, emergency lighting should be installed in locations where it is likely to be needed most - such as near exits or in hallways leading to different parts of the building.

Emergency lights must be installed in all common areas, escape routes and exits of multi-unit residential buildings, and government and commercial buildings occupied by employees, customers, and the general public. Installation needs to light hazards along an evacuation route such as stairs, corners and uneven paths, and firefighting equipment such as extinguishers and fire blankets.

Some other common locations that require emergency lighting are rooms with no lighting, no windows, lifts, large function rooms, different floor levels, toilets and bathrooms. Another kind of LED (bulbs) luminaire that provides safety in other premises is called a spitfire luminaire. These LED luminaires are located along exit paths and fire safety paths.